Sign In | Join Free | My fazendomedia.com |
|
Brand Name : Star merter
Model Number : CWDZ61Y
Place of Origin : China
MOQ : 1PC
Price : Negotiation
Payment Terms : T/T
Supply Ability : 30000 Piece/Month
Name : Hygienic Temperature Transmitter
Range : -50~150°C
Output : 4~20mA, PT100 (1/3B class)
Power supply : 9~36VDC
Accuracy : 0.25%FS, 0.5%FS
CWDZ61Y Hygienic Temperature Transmitter Medical technolog pharmaceutical industry food and beverage industry
CWDZ61Y hygienic temperature transmitter for hygienic applications. The whole material is 316L to meet the hygiene requirements. Laser welding leveling process with protection up to IP69K (washable). The surface in contact with the process medium adopts plasma polishing process, so that it has the characteristics of easy cleaning and corrosion resistance. In addition, it is equipped with a variety of sanitary process connections to easily match different working conditions.
Base parameters | |
Measuring medium | Liquids or gases, etc. (compatible with contact materials) |
Measuring range | -50~150℃ |
Output signal | 4~20mA |
Power supply | 9~36VDC |
precision | 0.25%FS,0.5%FS |
resolution | Analog output 0.02%FS |
Measuring cell | 1*Pt100(1/3B grade) |
Response time | ≈18s (according to IEC60751, 0.4m/s water flow, 10°C steps) |
Stable performance | ± 0.1% FS/year |
Between ons | 400ms |
Maximum power | ≤0.02Us(W) Note: Us=Supply voltage |
Load characteristics | Current type: load ≤{(Us-9)/0.02(Us=supply voltage)}Ω |
Degree of protection | IP69K Note: The above protection level refers to the electrical connection achieved after it is complete, and also depends on the electrical connection plug. |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ,500VDC |
Dielectric strength | 500VAC |
Output limits | |
The output is minimal | 4mA |
Output maximum | 20mA |
Overall material | |
Protective tube | 316 stainless steel (contact with the medium to be measured) |
Process connection | 316 stainless steel (contact with the medium to be measured) |
enclosure | 316L stainless steel |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) in accordance with IEC60068-2-6 standard |
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard |
![]() |
CWDZ61Y Hygienic Temperature Transmitter for Pharmaceutical / Food / Beverage Industry Images |